NB Nennweite | INTERNER DURCHMESSER (D) | PTFE LINER DICKE (T) | FLANSCH PCD | FLANSCHLOCH DURCHMESSER | Dichtleiste DIA (R / F) | MAXI. LÄNGE | PIPE ZEITPLAN | ||
(MM) | (Zoll) | (+1 MM) | (MM) | (MM) | (MM) | (MM) | (MM) | ||
25 | 1 | 19,5 | 3.3 | 79,4 | 15.9 | 51 | 3000 | 40 | |
40 | 1,5 | 33.8 | 3.3 | 98,4 | 15.9 | 73 | 3000 | 40 | |
50 | 2 | 45,4 | 3.3 | 120,6 | 19,0 | 92 | 3000 | 40 | |
80 | 3 | 70,8 | 3.3 | 152,4 | 19,0 | 127 | 3000 | 40 | |
100 | 4 | 95,2 | 3.8 | 190,5 | 19,0 | 157 | 3000 | 40 | |
150 | 6 | 145,1 | 4.5 | 241,3 | 22.2 | 216 | 3000 | 40 | |
200 | 8 | 197,4 | 5.0 | 298,4 | 22.2 | 270 | 3000 | 30 | |
250 | 10 | 249,3 | 6.0 | 362,0 | 25,4 | 324 | 3000 | 30 | |
300 | 12 | 300.1 | 6.0 | 431,8 | 25,4 | 381 | 3000 | 30 |
GEHÄUSE
- Pipe: 1. Nahtlose Carbon Steel ASTM A 106 Gr.B.Sch-40
2. ASTM A 312 TP 304, Sch-40 - Flansche: 1. Gebildet von IS 2062 Platten / ASTM A 105
2. ASTM A 351 Gr. CF 8 - Liner: PTFE in Übereinstimmung mit ASTM D 1457
OPTIONEN
- Rohr: Jacketed Spool Rohr kann auf Anfrage geliefert werden
- Flansche: DIN PN 10/16, BS 10, ASME 300, Misch
- Extras: Erdungsbolzen / Böckchen, Vent Extensions
- Material: Edelstahl
- Liner: HDPE / PP
HINWEIS
Spezieller Schwerlast PTFE-Liner für volles Vakuum zur Verfügung. Details können auf Anfrage zur Verfügung gestellt werden. Andere Flanschlochungen wie DIN 2632/2633, BS 10 Tabelle D, E oder F sind auf Anfrage ebenfalls verfügbar. Toleranz: ± 3,5 mm (0 bis 1mtr.) Und ± 5,0 mm (1 bis 3 mtr.) Klar ID für HDPE / PP ausgekleidete Rohre (DN / ID): 25/18, 40/32, 50 / 42,65 / 57, 80/67.
TEST & Prüfdaten
Harze sind konform zu den Anforderungen der ASTM F 1545-97 (2003)
- Hydraulische Test: 20 kg / cm 2 Nach Lining
- Spark-Test: 15 KV DC Nach dem Futter